80 Configuring the ViconNet System XX112-36-00 Rev 909 Kollector Hybrid Network Digital Video Recorder
Using the Central Failure Notification (CFN) Mechanism
The CFN mechanism enables Workstations and transmitter sites connected to the same Nucleus to receive
notifications indicating that certain applications have failed, for example, macro, recording and database
failures.
CFN increases the user's awareness of problems that could occur at unmanned remote sites. It sends
error/warning notifications, via the network, to other sites that share the same Nucleus. The notifying site is
the same one that handles the Nucleus.
The CFN mechanism is available only for the site that handles the Nucleus.
You can configure the duration for which the CFNs will be displayed by selecting the
option in the System Settings window, as described in the Configuring the Central Failure Notification (CFN)
Display section on page 82.
To activate the CFN mechanism:
1. From the ViconNet Main window, click . The Setup Site Selection window is displayed,
showing a list of all currently connected transmitters and Workstations, as shown on page 59.
2. Select the site with the Nucleus and click
. The System Settings window is displayed, as
shown on page 60.
3. Click
. The Central Failure Notification window is displayed.